ATM Fog Activation

atm_with_smoke

ATM Security Fog Generator

ATM SFG 2000

atm-fog-generator atm_with_smoke

Information or Request

The ATM SFG 2000 has been specifically developed for use in small to mid size areas where a full ATM Protection is required, but where reduced output is sufficient i.e. ATM protection, ATM Bunkers, front offices and ATM voult rooms.

The ATM SFG 2000 is a highly advanced and dedicated security product that has been developed with the goal of creating instant protection in case of an intrusion. All CIT Securuty Solutions products are fully compatible with, and can be integrated into, any modern detection and alarm system.
All ATM Security Fog Generator units feature built in brackets and plug-in connections for ease of installation. The unique and patented FOG sensor can easily be positioned with the built in confirmation system ( Optional Extra ).

The CIT Securuty Solutions ATM Security Fog Generators also support verification movement detectors to help eliminate unwanted activations from false alarms. Depending on the need, a CIT Security Solutions can consist of one or more Security Fog Generator units.

Features..

Uses Smokecloak FL600 fluid
Can be integrated with most existing alarm systems.
High quality Design
Can continuously generate smoke for up to 220 Seconds.
Calibrated fluid sensor
Battery Backup
Thermocouple temperature sensing with overheat protection.
Can be integrated with other Smokecloak products.
METAL CONSTRUCTION and Vandal resistant. (AS2201.1.1998)
Battery Back up
Cloaksensor® density control (exclusive to Smokecloak only)
allowing continuous auto Re-Activation
The state-of-the-art electronics, which incorporate microprocessor control, provide a broad range of error checking and reporting facilities which monitor and can be interfaced with your alarm system including.

Monitoring and Multi zone reporting options
Low Fluid.
System Trouble - Faulty or Low battery, Heat Exchanger, No Fluid, System Circuits fault, ect.
AC Fail.
System Activation.
Unit Tampers.
System Isolation.


Quality, Design Standards..
(Intruder alarm equipment and installed systems.)
BS7939:1999 (Security Fog Devices.)
Australian C tick Certified (Required by Australian Law)
Forskrift 212 (intruder alarm systems to Danish Standards )

Product specifications:

155m3in 30 Seconds
310m3in 60 Seconds
Uses SmokeCloak FL600 fluid

CIT Security Solutions™
Accessories

Security Fig Unit

acoustic security devices

Voice Module

Security lighting devices

ATM Security Fog Unit

 

Last Updated on Sunday, 01 March 2009 21:12
 
CIT Security Solutions CIT Security Solutions Pty Ltd
PO Box 30, Oakleigh, Victoria, Australia, 3166
Telephone: +61 3 9501 7300
Copyright © 2000 - 2009 CIT Security Solutions Pty Ltd
all rights reserved

ATM Gas Protection | ATM Protection | ATM Gas Detection | ATM Gas Suppression | ATM Cash Protection | ATM Security Accessories